Nailora Grow Strips certificate of analysis, lot KJF12501

One lot was tested for identity, label amounts, dissolving time and microbes. Heavy metals and pesticides were checked against a limit, with no measured figure.

This is IngredientMD's reissue of the manufacturer's certificate of analysis for the tested lot: the same figures, set so they are easier to read, with a line under each row saying where the result sits against its own limit. The manufacturer's certificate names no testing laboratory.

The full verification of Grow StripsThe same document as a PDF
Nailora Grow Strips certificate of analysis, lot KJF12501, page 1 of 4, reissued by IngredientMDNailora Grow Strips certificate of analysis, lot KJF12501, page 2 of 4, reissued by IngredientMDNailora Grow Strips certificate of analysis, lot KJF12501, page 3 of 4, reissued by IngredientMDNailora Grow Strips certificate of analysis, lot KJF12501, page 4 of 4, reissued by IngredientMD

Every row, as text

Label amounts Measured

Biotin 109.8% of label.

BiotinLabel: 5,000 mcg109.8% of labelabout 5,490 mcgLimit: not less than 90%LC-MS
FolateLabel: 400 mcg DFE (240 mcg folic acid)110.8% of labelabout 443 mcg DFE (266 mcg folic acid)Limit: not less than 90%HPLC
Vitamin D3Label: 20 mcg112.5% of labelabout 22.5 mcgLimit: not less than 90%

Identity Measured

Biotin, folate and vitamin D3 confirmed.

BiotinMatches the reference standardLimit: retention time matches the standardLC-MS
FolateMatches the reference standardLimit: retention time matches the standardHPLC
Vitamin D3Matches the reference standardLimit: retention time matches the standardHPLC

Heavy metals Limit test

Under the limit for all four.

Leadless than 3.0 ppmat most 0.3 mcg in a 100 mg stripLimit: not more than 3.0 ppm
Cadmiumless than 1.0 ppmat most 0.1 mcgLimit: not more than 1.0 ppm
Arsenicless than 1.0 ppmat most 0.1 mcgLimit: not more than 1.0 ppm
Mercuryless than 0.1 ppmat most 0.01 mcgLimit: not more than 0.1 ppm

A limit test: the certificate gives no measured value and names no method. A strip weighs 100 mg, so even at the limit the amounts are small.

Microbes Measured

50 cfu/g against a limit of 1,000. Four pathogens absent.

Total aerobic count50 cfu/gLimit: not more than 1,000 cfu/g
Yeast and mouldunder 10 cfu/gLimit: not more than 100 cfu/g
E. coliAbsent in 1 gLimit: absent
SalmonellaAbsent in 10 gLimit: absent
Pseudomonas aeruginosaAbsent in 1 gLimit: absent
Staphylococcus aureusAbsent in 1 gLimit: absent

The certificate names no method for these.

Pesticides Limit test

The certificate says it complies.

Specified pesticidesCompliesLimit: free from specified pesticides

The certificate names neither the pesticides nor the method.

Dissolving Measured

Dissolves in 38 seconds.

Disintegration time38 secondsLimit: not more than 60 seconds
Average weight100.20 mgLimit: 90 to 110 mg
Moisture4.40%Limit: 3.0 to 6.0%Karl Fischer

What this certificate of analysis does not cover

  • No testing lab is named and no test date is given. The manufacturer's certificate is dated 4 March 2026.
  • Heavy metals and pesticides are pass or fail, with no measured figure.
  • The closing remark reads "complies / does not comply" with neither struck out.
  • Each certificate speaks for the lot that was tested. It is representative, so it is not a test of the unit in your hands.